AS15.15-Z-0001-01A | Risk of death caused by coming into contact with high-voltage parts although ignition is turned off. | After ignition is turned OFF, only disconnect the plug on the ECI power pack after first waiting for 3 minutes. | Danger! |
N91 ECI ignition system power pack
Connector assignment: Pin 4, 5 Voltage supply, circuit (terminal) 87 Pin 7 Auxiliary voltage approx. 23 V for right ignition module Pin 8 Auxiliary voltage approx. 23 V for left ignition module Pin 9 Voltage approx. 180 V for right ignition module Pin 11 Ground for right ignition module Pin 12 Battery voltage for right ignition module Pin 13 Battery voltage for left ignition module Pin 14 Ground for left ignition module Pin 16 Voltage approx. 180 V for left ignition module |
||
P15.10-2042-06 |
After ignition is OFF there is still a voltage of more than 48 V at plugs 9 and 16 on the ECI ignition system power pack. Remove plug from ECI power pack unit only after first waiting for 3 minutes. The voltage is then no longer dangerous because the capacitor has had time to discharge. |
For safety reasons the 180 V may only be measured with the corresponding insulated measuring equipment and lines. |