GF09.41-P-3102M Charge air cooling circulation pump, location/task/function 14.5.02

ENGINE  275.950 /980 in MODEL 215


M44 Charge air cooler circulation pump

a Coolant hose connection on the suction side
b Coolant hose connection on the thrust side
c Electrical connection
 
    P09.41-2149-01

  Charge air cooling circulation pump position   GF09.41-P-3102-01K
  Charge air cooling circulation pump task Keep the charge air temperature below
70 °C by means of coolant circulation.
 
  Charge air cooling circulation pump function The circulation pump is actuated via a relay by the engine control unit.
Switching on:
Charge air temperature above approx.
47 °C
Switching off:
Charge air temperature below approx.
35 °C