GF14.30-P-2020SM | Component description of air pump switchover valve | 22.3.04 |
|
Y32 Air pump switchover valve
The air pump switchover valve is located at the front at the right cylinder bank. Task The air pump switchover valve controls the left and right air aspirator shutoff valves with vacuum pressure for the purpose of air injection. |
![]() | |
P14.30-2113-11 |
Design
1 Ventilation connection 2 Vacuum supply connection 3 Connection to the air shutoff valves a Armature disk b Return spring c Housing d Solenoid (coil) e Electrical connection f Rubber seal |
![]() | |
P07.10-0308-81 |
Function
1 Ventilation connection (atmospheric) 2 Vacuum supply connection (vacuum memory in intake manifold) 3 Connection to the air shutoff valves 4 Wiring connector A Air pump switchover valve energized (air shutoff valves discharged with vacuum pressure) B Air pump shutoff valve deenergized (air shutoff valves ventilated) |
![]() | |
P14.30-2114-75 |
The air pump switchover is actuated directly with a ground signal by the ME control unit when air injection is enabled (N3/10. Here the anchor plate (a) is pulled by the electromagnet (d) and the sealing rubber (f) shuts off connection 1 | The connection between port 2 and port 3 is opened. Thus there is a vacuum built up from the intake pipe to the aspirator shutoff valves.
In the deenergized state the link again exists between connection 1 and 3 through which air is admitted at connection 3. |