GF14.30-P-2100SM Component description of aspirator shutoff valve with integral check valve 22.3.04

ENGINE  113.986
ENGINE  113.987
ENGINE  113.988
ENGINE  113.989


126/1 Left aspirator shutoff valve
126/2 Right aspirator shutoff valve

For each cylinder head, an aspirator shutoff valve with integral check valve is located at the front of the engine.

Task
When air pump is switched off, the aspirator shutoff valves prevent air being inducted into the exhaust ports, as a result of the flow of the exhaust gases.
 
    P14.30-2115-11

Function

126a Vacuum diaphragm
126b Check valve

a Air to air pump switchover valve (vacuum build up)
b Injected air from the air pump
c Injected air to cylinder head

The aspirator shutoff valves are opened via the air pump switchover valve (Y32) through vacuum or closed through ventilation. The injected air to the electrical air pump (M33) can thus flow through when the aspirator shutoff valves are actuated.
When air injection is off, the check valve prevents the admission of exhaust gas in the vacuum diaphragm and thus protects these from dirt and thermal destruction.
 
    P14.30-2094-81