GF72.29-P-3007B | Power window one-touch up/down feature, function | 13.4.99 |
|
Function prerequisites
Voltage not too high or too low and Circuit 15 ON or circuit 15R ON Power windows synchronized Function not inhibited (version coding) Function The one-touch up/down feature is triggered by momentarily pressing the power window switch past the first catch point in the "close" or "open" direction. The corresponding left front door control module (N69/1)/right front door control module (N69/2)/rear control module /N22/6) reads in the switch status and actuates the associated power window motor (M10/3, M10/4, M10/5 or M10/6) until the position recognition feature indicates that the window is completely closed or opened. |
On non-synchronized windows the manual up/down feature is accomplished instead of the one-touch up/down feature. When the front side window is opened the associated rear side window can be closed only to the short stroke position. Function termination The one-touch up/down feature is terminated when the power window switch is actuated again or the pinch protection actuates while the window is rolling up the function prerequisites are no longer fulfilled. |
Power window position recognition, function | GF72.29-P-4000S | ||
Power window manual up/down feature, function | GF72.29-P-3006B | ||
Power window synchronization, function | GF72.29-P-4003S | ||
Power window short stroke, function | GF72.29-P-4005A | ||
Front driver-side door control module, location/purpose/design/function | GF72.29-P-4105S | ||
Front passenger-side door control module, location/purpose/design/function | GF72.29-P-4106S | ||
Rear control module, location/purpose/design | GF91.29-P-2111A | ||
Front power window motor, location/function | GF72.29-P-4108A | ||
Rear power window motor, location/function | GF72.29-P-4109A |